DC-DC Converter 2 W

Series

Picture

Input voltage
[VDC]

Output voltage single
[VDC]

Output current [mA]

Output voltage dual
[VDC]

Output current [mA]

Dimensions
LxWxH
[mm]

Features

URL

P2Afileadmin/HY_LINE/Pictures/Parametrical_Search/P2A.jpg4,5 .. 5,5
10,8 .. 13,2
13,5..16,5
21,6 .. 26,4
45,6..
50,4
3,3
5,0
7,2
9,0
12,0
15,0
18,0
24,0
400
400
270
222
167
133
111
83
SIL 4
11.7x6.0x10.2
- Unregulated output
- Single output
- -40° C .. +85° C
- Up to 3kV isolation
- Low ripple and noise
>>pdf>>
P2Bfileadmin/HY_LINE/Pictures/Parametrical_Search/P2B.jpg2,97..
3,63
4,5 .. 5,5
10,8 .. 13,2
21,6 .. 26,4
45,6..
50,4
3,3
5,0
7,2
9,0
12,0
15,0
18,0
24,0
600
400
270
222
167
133
111
83
±3
±5
±6
±7.2
±9
±12
±15
±24
3.3/3.3
5/5
7.2/7.2
9/9
12/12
15/15
5/3.3
5/7.2
5/9
5/12
5/15
±200
±111
±84
±67
±42
2x200
2x139
2x111
2x84
2x67
2x200
200/139
200/111
200/84
200/67
SIL 7
19.5x6.0x9.5
- Unregulated output
- Single output
- Dual output
- 2 isolated outputs
- -40° C .. +85° C
- Up to 6kV isolation
- Low ripple and noise
>>pdf>>
P2Cfileadmin/HY_LINE/Pictures/Parametrical_Search/P2C.jpg4,5 .. 5,5
10,8 .. 13,2
21,6 .. 26,4
45,6..
50,4
3,3
5,0
7,2
9,0
12,0
15,0
18,0
24,0
600
400
270
222
167
133
111
83
±3,3
±5,0
±7,2
±9,0
±12,0
±15,0
±18,0
±300
±200
±139
±111
±83
±67
±55
DIL 24
31.8x20.3x10.2
- Regulated output
- Single output
- Dual output
- Up to 6kV isolation
- -40° C .. +85° C
- Continuous short circuit protection
- Low ripple and noise
>>pdf>>
P2Dfileadmin/HY_LINE/Pictures/Parametrical_Search/P2D.jpg9 .. 18
18 .. 36
36 .. 72
3.3
5
7.2
9
12
15
18
24
600
400
270
222
167
133
111
83
±5
±7.2
±9
±12
±15
±24
±200
±140
±112
±83
±67
±42
31.8x20.3x10.2- 2:1 wide input range
- Single output
- Dual output
- Up to 3.5kV isolation
- -40° C .. +85° C
- Continuous short circuit protection
- Low ripple and noise
>>pdf>>
P2Efileadmin/HY_LINE/Pictures/Parametrical_Search/P2E.jpg9 .. 36
18 .. 75
3,3
5,0
12,0
15,0
500
400
167
133
±5,0
±12,0
±15,0
±200
±85
±65
26x12,5x9,3- 4:1 wide Input Range
- regulated Output
- single Output
- dual Output
- 1,5kV Isolation
- -40°C .. +75°C
- continuous Short Circuit protected
- remote control on / off
>>pdf>>
P2Ffileadmin/HY_LINE/Pictures/Parametrical_Search/P2F.jpg4,5 .. 18
9 .. 36
18 .. 75
3,3
5,0
12,0
15,0
500
400
167
133
±5,0
±12,0
±15,0
±200
±83
±66
21,8x11x9,2- 4:1 wide Input Range
- regulated Output
- single Output
- dual Output
- 1,6kV Isolation
- -40°C .. +71°C
- continuous Short Circuit protected
- remote control on / off
>>pdf>>
P2Ufileadmin/HY_LINE/Pictures/Parametrical_Search/P2U.jpg4,5 .. 9
9 .. 18
18 .. 36
36 .. 72
3,3
3,6
5,0
7,2
9,0
12,0
15,0
18,0
24,0
500
500
400
278
222
167
133
111
83
±3,3
±3,6
±5,0
±7,2
±9,0
±12,0
±15,0
±18,0
±24,0
±250
±250
±200
±139
±111
±83
±67
±56
±42
21,8x11x9,2- 2:1 wide input range
- Single output
- Dual output
- up to 3kV isolation
- -40°C .. +85°C
- Continuous short circuit protection
- low ripple and noise
- remote control on / off
>>pdf>>
P2Vfileadmin/HY_LINE/Pictures/Parametrical_Search/P2V.jpg9 .. 18
18 .. 36
36 .. 72
3.3
5
7.2
9
12
15
18
24
600
400
270
223
167
134
111
84
±5
±7.2
±9
±12
±15
±24
±200
±140
±112
±83
±67
±42
31.8x20.3x10.2- 2:1 wide input range
- Single output
- Dual output
- Up to 3.5kV isolation
- -40° C .. +85° C
- Continuous short circuit protection
- Low ripple and noise
>>pdf>>

Series

Picture

Input voltage
[VDC]

Output voltage single
[VDC]

Output current [mA]

Output voltage dual
[VDC]

Output current [mA]

Dimensions
LxWxH
[mm]

Features

URL

P2Xfileadmin/HY_LINE/Pictures/Parametrical_Search/P2X.jpg4.5 .. 9
9 .. 18
18 .. 36
36 .. 72
3,3
5,0
9,0
12,0
15,0
24,0
500
400
222
167
133
83
±3,3
±5,0
±9,0
±12,0
±15,0
±24,0
±300
±200
±111
±83
±67
±42
DIL 16
23.4x14.0x10.2
- 2:1 wide input range
- Single output
- Up to 3kV isolation
- -40° C .. +85° C
- Continuous short circuit protection
- Low ripple and noise
>>pdf>>
P2Yfileadmin/HY_LINE/Pictures/Parametrical_Search/P2Y.jpg9 .. 36
18 .. 72
3.3
5
7.2
9
12
15
18
24
600
400
270
222
167
133
111
83
±3.3
±5
±7.2
±9
±12
±15
±24
±300
±200
±140
±112
±83
±67
±42
31.8x20.3x10.2- 4:1 wide input range
- Single output
- Dual output
- Up to 3.5kV isolation
- -40° C .. +85° C
- Continuous short circuit protection
- Low ripple and noise
>>pdf>>
P2Zfileadmin/HY_LINE/Pictures/Parametrical_Search/P2Z.jpg4,5 .. 5,5
10,8 .. 13,2
21,6 .. 26,4
45,6..
50,4
3.3
5
7.2
9
12
15
18
24
600
400
270
222
167
133
111
83
±5
±9
±12
±15
±24
5/5
9/9
12/12
15/15
5/3.3
5/7.2
5/9
5/12
5/15
±200
±111
±84
±67
±42
2x200
2x111
2x84
2x67
2x200
200/139
200/111
200/84
200/67
DIL 14
20.3x10.2x6.9
- Unregulated output
- Single output
- Dual output
- 2 isolated outputs
- Up to 6kV isolation
- -40° C .. +85° C
- Low ripple and noise
>>pdf>>